KROHNE Vietnam, OPTIMASS 1400 C, OPTIMASS 1400 C KROHNE Vietnam, đại lý KROHNE Vietnam

 

KROHNE Vietnam

Mass flowmeter
Base Model: OPTIMASS 1400 C
Type: OPTIMASS 1400 C Compact system
Flow Sensor: OPTIMASS 1000-S 50 Straight twin tube system
made of Stainless Steel 318
Process pressure: 49.6 bar @ 20°C/40 bar @ 130°C
719 PSI @ 68°F/580 PSI @ 266°F
Process temperature: -40°C to 130°C
Ex-protection: Ex d ia ; Connection: 2" ASME 300 lb
Sealing face: RF to ASME B16.5
Housing :Material Stainless Steel 304L acc. to NAMUR NE 132
Typical burst pressure > 100 bar
protection class: EN 60 529 IP 66/IP 67 / NEMA 250 Type 4X
mounting length: 906 mm (+/- 5 mm) calibration: 3 pt mass flow calibration
Converter type: MFC 400 C Functional Safety without SIL
Type: MFC 400 C – Ex compact model
Accuracy: up to +/- 0.05 % of MV - see TDS
Power supply: 12-24 V DC (9-31 V)
Ex-protection: Flameproof enclosure "d"
II 1/2 G - Ex db ia IIC T6...T1 Ga/Gb; II 2 D - Ex tb IIIC T185°C Db
PTB 12 ATEX 2014 X - IECEx PTB 12.0042 X terminalbox Ex "d"
Cable connection: 3 metallic 1/2" NPT adaptors
Process diagnostic   Standard; Converter housing   Standard, Aluminium; Communication: Basic I/O
1. Current output HART, active / passive
2. Pulse / status outp. passive
3. Status output passive
4. Status out / control passive
APPLICATION DATA
Medium: LPG LIQUID
Flow Range: 0 ... 50 m3/h
Density: 0,56 kg/l
Viscosity: 0,16 cP
Temperature: 65 °C
Pressure: 25 bar